A DIN series that specifies technical delivery conditions for fasteners by part. The strength, plating, and stainless steel parts moved to ISO, and some, such as the part for high- and low-temperature components (-13), are current.
Status: Differs by part
Key points
- DIN 267-13 is the current standard specifying special mechanical properties of bolted connection components used at −200 °C to +700 °C.
- The old-system nut strength DIN 267-4 was withdrawn and moved to the ISO 898-2 series (DIN EN 20898-2).
- Electroplating DIN 267-9 → ISO 4042, hot-dip galvanizing DIN 267-10 → ISO 10684, stainless steel DIN 267-11 → ISO 3506-1 · -2 · -3.
- Fine-thread nut strength DIN 267-23 moved to ISO 898-6, and ISO 898-6 was in turn merged into ISO 898-2 (2012 edition).
- The hardness grades of nuts without proof load (DIN 267-24), microencapsulated adhesive coating (DIN 267-27), and thread-forming screws of 10.9 (DIN 267-30) are current.
- Read a citation of "DIN 267" on an old drawing by checking the part number and replacing it with the current ISO.
Status of main parts of DIN 267
| Part | Content | Status |
|---|---|---|
| DIN 267-2 | Surface roughness of product grades A and B | Current |
| DIN 267-4 | Nut property classes (old system) | Withdrawn → ISO 898-2 series |
| DIN 267-9 | Electroplated parts | Withdrawn → ISO 4042 |
| DIN 267-10 | Hot-dip galvanized parts | Withdrawn → ISO 10684 |
| DIN 267-11 | Stainless steel parts | Withdrawn → ISO 3506-1 · -2 · -3 |
| DIN 267-13 | Bolted connection components for −200 to +700 °C | Current |
| DIN 267-23 | Fine-thread nut strength | Withdrawn → ISO 898-6 → now ISO 898-2 |
| DIN 267-24 | Hardness grades of nuts without proof load | Current |
| DIN 267-27 | Bolts with microencapsulated adhesive coating | Current |
| DIN 267-30 | 10.9 metric thread-forming screws | Current |
Based on the status and replacement shown in the DIN Media catalog.
Checks for BOMs and buying
- Do not directly replace high- and low-temperature bolting with a DIN 267-13 requirement by general ISO 898-1 property class bolts. ISO 898-1 parts assume use at −50 to +150 °C.
- For an old drawing with a remaining DIN 267-10 (hot-dip galvanizing) requirement, check against ISO 10684 (overtapping, etc.).
- "DIN 267" without a part number is meaningless. Confirm which part it is.
ISO: official search ↗ · DIN: official search ↗
These links go to the issuing bodies; they are not the verification source of individual values.
Basis: DIN 267-2 · DIN 267-4 · DIN 267-9 · DIN 267-10 · DIN 267-11 · DIN 267-13 · DIN 267-23 · DIN 267-24 · DIN 267-27 · DIN 267-30 · ISO 898-2 · library-wide review 2026-10 (no per-item review date). Project edition, tolerances and service conditions must be confirmed against the standard text and supplier documents. Do not estimate unconfirmed values.