Applicable standards and designations to distinguish
The standards below are not a list of interchangeable substitutes with the same dimensions and requirements. We compare against the standard and edition in your BOM and the drawing requirements.
| Body / basis | Standard and scope |
|---|---|
| ASME | Dimensions are per ASME B18.2.6 (original not held) |
| ASTM | ASTM F959 (Type 325 · 490, etc., confirmed from the standard document at quotation) |
Differences to check before buying
- The type must match the bolt grade: A325 Type 1 → 325, A490 Type 1 → 490, weathering (Type 3) bolts → 325-3 · 490-3.
- Field inspection is judged by the number of protrusions into which the gap gauge does not fit (the acceptance criteria follow the structural connection specification).
- For the 490 type, the standard has no gap criterion for mechanical zinc, so confirm the plating specification.
Materials and surface treatments we distinguish when reviewing
Material and strength designations
DTI Type 325 · DTI Type 490
Surface treatment designations
Uncoated (rust-preventive oil) · Mechanical zinc (ASTM B695 Class 55)
These are review items, not a statement that every combination is available. Confirm against the applicable standard and your service conditions.
What to put in the RFQ for this item
No new form is needed: send your existing BOM, notes or request. Missing specifications come back as questions.
Item: Direct Tension Indicator Applicable standard and edition: [as written in your BOM or drawing] Nominal size, pitch, length: [exactly as written] Material and grade / surface treatment: [your requirement] Quantity and unit / required date and delivery site: [your request] Documents: [e.g. EN 10204 3.1, CoC]Send a BOM or RFQ →
Compiled from the public catalog designations and guidance. A review date is not recorded per item. For design and contracts, check the applicable standard text and your drawing; do not estimate unconfirmed values.