Basis: DIN 6923 = EN 1661 = ISO 4161 · Cross-checked against three or more manufacturer and distributor datasheets (not yet checked against the original standard) · Units mm
| Nominal size | Pthread pitch P | c_minflange edge thickness c min | dc_maxflange diameter dc max | dw_minbearing face (contact) diameter dw min | e_minwidth across corners e min | m_maxnut height m max | m_minnut height m min | s_maxwidth across flats s nominal = max |
|---|---|---|---|---|---|---|---|---|
| M5 | 0.8 | 1 | 11.8 | 9.8 | 8.79 | 5 | 4.7 | 8 |
| M6 | 1 | 1.1 | 14.2 | 12.2 | 11.05 | 6 | 5.7 | 10 |
| M8 | 1.25 | 1.2 | 17.9 | 15.8 | 14.38 | 8 | 7.6 | 13 |
| M10 | 1.5 | 1.5 | 21.8 | 19.6 | 16.64 | 10 | 9.6 | 15 |
| M12 | 1.75 | 1.8 | 26 | 23.8 | 20.03 | 12 | 11.6 | 18 |
| M16 | 2 | 2.4 | 34.5 | 31.9 | 26.75 | 16 | 15.3 | 24 |
| M20 | 2.5 | 3 | 42.8 | 39.9 | 32.95 | 20 | 18.9 | 30 |
Need Hexagon Nut with Flange to this standard? Send the BOM or drawing as it is. We check against the applicable standard and then quote in KRW for delivery within Korea.
Send a BOM or RFQ →About this item
Used for fastening sheet metal and frames, with a wide bearing face that doubles as a washer. The serrated type has teeth on the bearing face that prevent loosening.
Basis and limits of this table
- Cross-checked against three or more manufacturer and distributor datasheets (not yet checked against the original standard)
- This is not a table from the original standard. Only the values and the standard number are arranged in Boltnote's own format.
- Nominal sizes and columns that could not be confirmed are left out, not estimated.
- For design, inspection and contracts, use the latest edition of the applicable standard and your drawing. Values can change when a standard is revised.
- Checked 2026-10.
- To cite this table: Boltnote Hexagon Nut with Flange dimension table, https://boltnote.net/en/tables/hexagon-nut-with-flange, updated 2026-11-18. Give the basis line above with it.
Sizes or lengths not in the table
Send the BOM or drawing as it is. We check the required dimensions against the applicable standard before quoting.