Dimensions
Basis: ISO 8733 · Cross-checked against three or more manufacturer and distributor datasheets (not yet checked against the original standard) · Scope: Non-hardened type (ISO 8733) dimensions only — the chamfers a and c and the length range of the hardened type (ISO 8735) are not included (that the thread and hole dimensions of the hardened type are the same could not be confirmed from 3 or more public sources). · Units mm
| Nominal size | d1nominal diameter d1 | d2internal thread nominal d2 (metric thread, 4 = M4) | d3thread entry diameter d3 | t1full thread depth t1 | t2_minhole depth t2 (min) | t3entry depth t3 | c1_unhardthread-side chamfer c1 (≈, non-hardened) |
|---|---|---|---|---|---|---|---|
| 6 | 6 | 4 | 4.3 | 6 | 10 | 1 | 0.8 |
| 8 | 8 | 5 | 5.3 | 8 | 12 | 1.2 | 1 |
| 10 | 10 | 6 | 6.4 | 10 | 16 | 1.2 | 1.2 |
| 12 | 12 | 6 | 6.4 | 12 | 20 | 1.2 | 1.6 |
| 16 | 16 | 8 | 8.4 | 16 | 25 | 1.5 | 2 |
| 20 | 20 | 10 | 10.5 | 18 | 28 | 1.5 | 2.5 |
| 25 | 25 | 16 | 17 | 24 | 35 | 2 | 3 |
| 30 | 30 | 20 | 21 | 30 | 40 | 2 | 4 |
| 40 | 40 | 20 | 21 | 30 | 40 | 2.5 | 5 |
| 50 | 50 | 24 | 25 | 36 | 50 | 2.5 | 6.3 |
Need Parallel Pin with Internal Thread to this standard? Send the BOM or drawing as it is. We check against the applicable standard and then quote in KRW for delivery within Korea.
Send a BOM or RFQ →About this item
A dowel pin for blind holes. A pulling bolt can be screwed into the internal thread at the end to disassemble it.
Basis and limits of this table
- Cross-checked against three or more manufacturer and distributor datasheets (not yet checked against the original standard)
- Scope: Non-hardened type (ISO 8733) dimensions only — the chamfers a and c and the length range of the hardened type (ISO 8735) are not included (that the thread and hole dimensions of the hardened type are the same could not be confirmed from 3 or more public sources).
- This is not a table from the original standard. Only the values and the standard number are arranged in Boltnote's own format.
- Nominal sizes and columns that could not be confirmed are left out, not estimated.
- For design, inspection and contracts, use the latest edition of the applicable standard and your drawing. Values can change when a standard is revised.
- Checked 2026-10.
- To cite this table: Boltnote Parallel Pin with Internal Thread dimension table, https://boltnote.net/en/tables/parallel-pin-with-internal-thread, updated 2026-11-18. Give the basis line above with it.
Sizes or lengths not in the table
Send the BOM or drawing as it is. We check the required dimensions against the applicable standard before quoting.