Applicable standards and designations to distinguish
The standards below are not a list of interchangeable substitutes with the same dimensions and requirements. We compare against the standard and edition in your BOM and the drawing requirements.
| Body / basis | Standard and scope |
|---|---|
| ASME | ASME B18.2.2 (heavy hex · heavy hex jam) |
| ASTM | ASTM A194/A194M · ASTM A563 Grade DH (structural, anchor) |
Differences to check before buying
- Plant nuts over 1 in use 8UN as the default. If UNC is needed, please state it in the order.
- The width across flats of a heavy nut is larger than that of a general nut of the same diameter (example: 1/2 in heavy 7/8, 3/4 in heavy 1-1/4). Check the tool and bearing face.
- If A194 Grade 4 is stated in an old specification, first check whether it can be supplied; if difficult, supply after approval of a Grade 7 substitution.
- 2HM and 7M are grades with a hardness upper limit (235–237 HB depending on the source) and are used for sour environment specifications.
- For the mating nut of a low-temperature stud (A320 L7 family), order an impact-tested nut (marked L).
- Plating and coating are applied only when specified. Hot-dip galvanized nuts are tapped oversize after plating, so they are treated as a set with the stud.
Materials and surface treatments we distinguish when reviewing
Material and strength designations
ASTM A194 2H · ASTM A194 2HM · ASTM A194 7 · ASTM A194 7M · ASTM A194 16 · ASTM A194 8 · ASTM A194 8M · ASTM A563 DH
Surface treatment designations
Uncoated (rust-preventive oil) · PTFE coating · Hot-dip galvanizing (ASTM F2329, nut oversize tapped) · Zinc-nickel plating
These are review items, not a statement that every combination is available. Confirm against the applicable standard and your service conditions.
What to put in the RFQ for this item
No new form is needed: send your existing BOM, notes or request. Missing specifications come back as questions.
Item: Heavy Hex Nut (Nut Only) Applicable standard and edition: [as written in your BOM or drawing] Nominal size, pitch, length: [exactly as written] Material and grade / surface treatment: [your requirement] Quantity and unit / required date and delivery site: [your request] Documents: [e.g. EN 10204 3.1, CoC]Send a BOM or RFQ →
Compiled from the public catalog designations and guidance. A review date is not recorded per item. For design and contracts, check the applicable standard text and your drawing; do not estimate unconfirmed values.