Specification for carbon steel and alloy steel nuts for general structural and machine use. It sets strength grades from Grade A to DH and DH3, and is used as the mating nut for A307, F3125, and A354 bolts.
Status: Current
Key points
- Inch grades (A, C, C3, D, DH, DH3, etc.) and metric property classes are covered in one combined inch-metric standard (A563/A563M).
- C3 and DH3 are weathering steel nuts and mate with weathering (Type 3) bolts.
- It covers hex and hex flange nuts, and an appendix gives guidance on the suitable nut grade for each bolt type.
- Unless prevented in the order, the manufacturer may supply a nut of a higher grade instead.
- Nuts mated to hot-dip galvanized bolts are usually re-tapped larger after plating (overtapped), and galvanized DH is given additional lubrication.
A563 mating nuts by representative bolt
| Bolt | Mating nut (A563) | Remarks |
|---|---|---|
| A307 Grade A | A (hex for 1-1/2" or less, heavy above) | General use |
| A307 Grade B | A heavy | For cast iron flanges |
| F3125 A325 | DH (for uncoated Type 1, also C · C3 · D · DH3) | Galvanized: DH overtapped and lubricated |
| F3125 A490 | DH · DH3 | Galvanizing not allowed |
| A354 BC / BD | C heavy (galvanized BC: DH) / DH heavy | A354-17 scope clause |
Based on the A307-21 scope clause, RCSC 2025 Table 2.2, and the A354-17 scope clause.
Checks for BOMs and buying
- A563 DH and A194 2H are different standards (in structural sets, 2H can be used instead of DH). For high-temperature, high-pressure flange bolting, specify nuts to A194.
- Do not mix non-overtapped nuts with galvanized bolts, or overtapped nuts with uncoated bolts.
- Mate DH3 and C3 weathering nuts with weathering (Type 3) bolts.
Equivalent and superseding standards
- ASME SA-563 ASME Section II Part A adopted edition
- ISO 898-2 Metric nut property class (thread system differs)
These links go to the issuing bodies; they are not the verification source of individual values.
Basis: ASTM A563/A563M · library-wide review 2026-10 (no per-item review date). Project edition, tolerances and service conditions must be confirmed against the standard text and supplier documents. Do not estimate unconfirmed values.