boltnoteSend an RFQ →

Home › Standards glossary › Surface treatment and corrosion › Hot-dip galvanized nut overtapping

Hot-dip galvanized nut overtapping

CommonConcept

Overtapped nuts for hot-dip galvanized bolts

← Back to topicSend a BOM or RFQ →

Tapping the nut larger than standard after plating, so that the thick coating on a hot-dip galvanized bolt fits. Thread engagement is reduced and assembly strength falls, so the method of pairing a nut of one property class higher is used.

Key points

  • In ISO 10684, the nut (internal thread) is tapped after plating, and re-tapping is not permitted.
  • The tolerance is 6AZ or 6AX (ISO 965-5), and Z or X is stamped after the nut property class marking.
  • Because engagement is reduced, the nut threads may strip first. ISO 10684 Annex F (informative) deals with the strength of hot-dip galvanized bolt and nut assemblies.
  • For M8 and M10 overtapped nuts, the proof load is set separately, lower than the ISO 898-2 value.
  • For inch standards, ASTM A563 covers overtapping and grades of galvanized nuts. A325 galvanized sets use A563 DH nuts that are overtapped and lubricated, and the set undergoes a rotational capacity test.
  • In inch structural work, only hardened nuts that keep their strength after overtapping (A563 DH·DH3, A194 2H) are considered suitable as overtapped coated nuts (RCSC 2025).
  • Nuts mechanically galvanized (ASTM B695 Class 55) are also overtapped according to ASTM A563 (RCSC 2025).

Hot-dip galvanized bolts and mating nuts

BoltOvertapped nutBasis
F3125 A325A563 DH, lubricated + set rotational capacity testASTM F3125 · A563
A193 B7A194 2H (hardened nut)RCSC 2025 commentary

Overtap limits are ISO 965-5 for metric and ASTM A563 for inch. The inch rows are based on RCSC 2025.

Checks for BOMs and buying

  • If an overtapped nut is used on an ungalvanized or electro-zinc bolt, engagement is insufficient and the threads may strip. Overtapped nuts are only for hot-dip galvanized bolts.
  • If the BOM has only "HDG nut" without a nut grade, check the mating bolt grade and the nut property class.
  • Do not re-tap on site because a plated nut will not go on. ISO 10684 does not permit re-tapping, so get a set again.
  • Hot-dip galvanizing of A490 is itself prohibited, so there is no overtapped nut combination either.

ASTM: official search ↗ · ISO: official search ↗

These links go to the issuing bodies; they are not the verification source of individual values.

Basis: ISO 10684 · ISO 965-5 · ISO 898-2 · ASTM A563 · ASTM F3125/F3125M · ASTM A194/A194M · RCSC Specification (2025) · library-wide review 2026-10 (no per-item review date). Project edition, tolerances and service conditions must be confirmed against the standard text and supplier documents. Do not estimate unconfirmed values.