Applicable standards and designations to distinguish
The standards below are not a list of interchangeable substitutes with the same dimensions and requirements. We compare against the standard and edition in your BOM and the drawing requirements.
| Body / basis | Standard and scope |
|---|---|
| ASME | ASME B1.1 (UNC 2A) |
| ASTM | F1554 Grade 36 · 55 · 105 · A563 (nut) · F436 Type 1 (washer) · F2329 (hot-dip galvanizing) · B695 Class 55 (mechanical zinc) |
Differences to check before buying
- F1554 is the standard for anchor bolts embedded in concrete foundations. The grades are 36, 55 and 105, distinguished by the color of the protruding end (blue, yellow, red).
- Length, thread length, hook length and projection length are manufactured from the foundation drawing. If there is no drawing, please state the diameter, embedment depth and projection length.
- Grade 105 exists only for 3" and under. The mating nut is supplied as an A563 DH heavy hex nut.
- Hot-dip galvanized anchor bolts are shipped in the same container as the overtapped nuts. The zinc processes of bolt and nut are not mixed.
- For Grade 105 hot-dip galvanizing, the pretreatment (pickling) method is agreed at quotation.
- Pump foundation anchor bolts are often not included in the equipment supply scope unless specified, so separate purchase is needed.
- The A307 Grade C anchor bolt designation has changed to F1554 Grade 36.
Materials and surface treatments we distinguish when reviewing
Material and strength designations
Grade 36 · Grade 55 · Grade 105
Surface treatment designations
Unplated · Hot-dip galvanizing (ASTM F2329) · Mechanical zinc (ASTM B695 Class 55) · Zinc plating on the protruding threaded portion only (to be agreed)
These are review items, not a statement that every combination is available. Confirm against the applicable standard and your service conditions.
What to put in the RFQ for this item
No new form is needed: send your existing BOM, notes or request. Missing specifications come back as questions.
Item: Anchor Bolt Applicable standard and edition: [as written in your BOM or drawing] Nominal size, pitch, length: [exactly as written] Material and grade / surface treatment: [your requirement] Quantity and unit / required date and delivery site: [your request] Documents: [e.g. EN 10204 3.1, CoC]Send a BOM or RFQ →
Compiled from the public catalog designations and guidance. A review date is not recorded per item. For design and contracts, check the applicable standard text and your drawing; do not estimate unconfirmed values.