boltnoteSend an RFQ →

Home › Products › Studs & Threaded Rods › Anchor Bolt

FASTENER PRODUCT GUIDE

Anchor Bolt

Conditionally sourced itemCheck inch designations

A flat washer hardened by heat treatment, used for high-strength structural bolts, B7 studs and anchor bolts. Specified by ASTM F436/F436M (Type 1 and 3).

Anchor Bolt reference 3D shape
Reference rendering · not a product photo
Dimensions, material and surface treatment are confirmed against your specification.

Applicable standards and designations to distinguish

The standards below are not a list of interchangeable substitutes with the same dimensions and requirements. We compare against the standard and edition in your BOM and the drawing requirements.

Anchor Bolt catalog standard designations
Body / basisStandard and scope
ASMEASME B1.1 (UNC 2A)
ASTMF1554 Grade 36 · 55 · 105 · A563 (nut) · F436 Type 1 (washer) · F2329 (hot-dip galvanizing) · B695 Class 55 (mechanical zinc)

Differences to check before buying

  • F1554 is the standard for anchor bolts embedded in concrete foundations. The grades are 36, 55 and 105, distinguished by the color of the protruding end (blue, yellow, red).
  • Length, thread length, hook length and projection length are manufactured from the foundation drawing. If there is no drawing, please state the diameter, embedment depth and projection length.
  • Grade 105 exists only for 3" and under. The mating nut is supplied as an A563 DH heavy hex nut.
  • Hot-dip galvanized anchor bolts are shipped in the same container as the overtapped nuts. The zinc processes of bolt and nut are not mixed.
  • For Grade 105 hot-dip galvanizing, the pretreatment (pickling) method is agreed at quotation.
  • Pump foundation anchor bolts are often not included in the equipment supply scope unless specified, so separate purchase is needed.
  • The A307 Grade C anchor bolt designation has changed to F1554 Grade 36.
Materials and surface treatments we distinguish when reviewing

Material and strength designations

Grade 36 · Grade 55 · Grade 105

Surface treatment designations

Unplated · Hot-dip galvanizing (ASTM F2329) · Mechanical zinc (ASTM B695 Class 55) · Zinc plating on the protruding threaded portion only (to be agreed)

These are review items, not a statement that every combination is available. Confirm against the applicable standard and your service conditions.

What to put in the RFQ for this item

No new form is needed: send your existing BOM, notes or request. Missing specifications come back as questions.

Item: Anchor Bolt
Applicable standard and edition: [as written in your BOM or drawing]
Nominal size, pitch, length: [exactly as written]
Material and grade / surface treatment: [your requirement]
Quantity and unit / required date and delivery site: [your request]
Documents: [e.g. EN 10204 3.1, CoC]
Send a BOM or RFQ →

Compiled from the public catalog designations and guidance. A review date is not recorded per item. For design and contracts, check the applicable standard text and your drawing; do not estimate unconfirmed values.

Items to compare

Reference rendering · not a product photo