Dimensions
Basis: DIN 3570 · Cross-checked against three or more manufacturer and distributor datasheets (not yet checked against the original standard) · Units mm
| Nominal size | ainner width a (inner width between tube centers) | dthread diameter d (M, mm) | Pthread pitch P (coarse thread) | bthread length b | hheight h1 (overall height) | d1_minapplicable tube outside diameter d1 min | d1_maxapplicable tube outside diameter d1 max |
|---|---|---|---|---|---|---|---|
| DN20 | 30 | 10 | 1.5 | 40 | 70 | 25 | 26.9 |
| DN25 | 38 | 10 | 1.5 | 40 | 76 | 30 | 33.7 |
| DN32 | 46 | 10 | 1.5 | 50 | 86 | 38 | 42.4 |
| DN40 | 52 | 10 | 1.5 | 50 | 92 | 44.5 | 48.3 |
| DN50 | 64 | 12 | 1.75 | 50 | 109 | 57 | 60.3 |
| DN80 | 94 | 12 | 1.75 | 50 | 138 | 88.9 | 88.9 |
Need U-Bolt to this standard? Send the BOM or drawing as it is. We check against the applicable standard and then quote in KRW for delivery within Korea.
Send a BOM or RFQ →Basis and limits of this table
- Cross-checked against three or more manufacturer and distributor datasheets (not yet checked against the original standard)
- This is not a table from the original standard. Only the values and the standard number are arranged in Boltnote's own format.
- Nominal sizes and columns that could not be confirmed are left out, not estimated.
- For design, inspection and contracts, use the latest edition of the applicable standard and your drawing. Values can change when a standard is revised.
- Checked 2026-10.
- To cite this table: Boltnote U-Bolt dimension table, https://boltnote.net/en/tables/u-bolt, updated 2026-11-18. Give the basis line above with it.
Sizes or lengths not in the table
Send the BOM or drawing as it is. We check the required dimensions against the applicable standard before quoting.