A bolt made by bending a rod into a U shape with threads at both ends, used to fix a pipe to a support. Metric is specified by DIN 3570 (dimensions by pipe size), inch by ASME B18.31.5 (bent bolt) or the pipe support drawing.
Key points
- A U-bolt is called by pipe size (25A, 50A, DN50, 2") rather than thread diameter. Write the pipe size and thread together.
- DIN 3570 sets the thread, inside width and leg spacing for each pipe size, so it is easy to match the hole spacing of the support.
- ASME B18.31.5 covers the dimensions and ordering notation of bent bolts such as U-bolts, J-bolts, hook bolts and bent eye bolts.
- KS and JIS steel pipes (A designation) and ISO steel pipes differ slightly in outside diameter, and coated or insulated pipes have a larger outside diameter.
- Decide together whether 2 nuts are included and whether washers are needed.
Checks for BOMs and buying
- If the pipe outside diameter (including insulation and coating) is not written, the inside width may not fit.
- Check from the support drawing whether it is for fixing or for guiding where the pipe can move. The tightening degree differs.
- Use overtapped nuts for hot-dip galvanized U-bolts.
- It is a different item from "bando" (band-type pipe clamp).
ASTM: official search ↗ · ASME: official search ↗ · DIN: official search ↗
These links go to the issuing bodies; they are not the verification source of individual values.
Basis: DIN 3570 · ASME B18.31.5 · ASTM A307 · library-wide review 2026-10 (no per-item review date). Project edition, tolerances and service conditions must be confirmed against the standard text and supplier documents. Do not estimate unconfirmed values.