Specification for general-use Q&T steel hex cap screws, bolts, and studs. The thicker the diameter, the lower the minimum tensile strength: 120, 105, and 90 ksi; it covers 1/4" to 3".
Status: Current
Key points
- Minimum tensile strength: 120 ksi for 1" or less, 105 ksi for over 1" to 1-1/2", and 90 ksi for 1-3/4" to 3" (about 827, 724, and 621 MPa, converted values).
- Type 1 is carbon steel, carbon boron steel, alloy steel, or alloy boron steel; Type 3 is weathering steel.
- Quenched and tempered fasteners for general machine use (General Use) in sizes 1/4" to 3".
Checks for BOMs and buying
- A449 over 1-1/2" is 90 ksi (about 621 MPa), considerably lower than class 8.8 (nominal tensile strength 800 MPa). Do not regard it as a substitute for 8.8.
- Even for the same A449, strength differs by diameter range, so match the certificate values to the diameter range.
- Do not substitute A449 for high-strength bolts for steel structure connections (F3125).
Equivalent and superseding standards
- ASME SA-449 ASME Section II Part A adopted edition
ASTM: official search ↗ · ASME: official search ↗
These links go to the issuing bodies; they are not the verification source of individual values.
Basis: ASTM A449 · ASME B16.5 · library-wide review 2026-10 (no per-item review date). Project edition, tolerances and service conditions must be confirmed against the standard text and supplier documents. Do not estimate unconfirmed values.