Specification for a corrosion-protective coating for fasteners using a water-based zinc/aluminum dispersion inorganic basecoat (with optional sealer or topcoat). It was withdrawn in 2025 and consolidated into the zinc flake standard ASTM F3393.
Status: Withdrawn (→ ASTM F3393, 2025)
Key points
- A non-electrolytic coating applying a water-based zinc/aluminum dispersion inorganic basecoat by dip-spin, dip-drain, or spray, to which a sealer or topcoat can be added.
- The basecoat came in chromium-containing (C) and chromium-free (NC) types, and Grades were divided by minimum basecoat thickness.
- The RCSC Specification (2020) allowed F1136 Grade 3 (Grade 5 for nuts), F2833 Grade 1, and F3019 Grade 4 for structural bolts.
- It was withdrawn in 2025, and F3393 (zinc flake coating system) replaces F1136/F1136M, F2833, and F3019/F3019M together. F3393 coatings are supplied without hexavalent (Cr6+) chromium.
- If there is no acid or phosphate pretreatment (alkaline cleaning, blasting), the process itself is regarded as not causing internal hydrogen embrittlement, so it is used on high-strength bolts.
Checks for BOMs and buying
- Check the "F1136 Grade 3" on an old drawing against the corresponding grade of the current F3393.
- The chromium-containing (C) type may not suit RoHS-regulated items, so check that it is the chromium-free type.
- The coating changes the friction coefficient, so the relationship between torque and clamping force changes.
Equivalent and superseding standards
- ASTM F3393 Successor consolidated standard (zinc flake coating system, no hexavalent (Cr6+) chromium)
- ISO 10683 Metric fastener zinc flake coating
These links go to the issuing bodies; they are not the verification source of individual values.
Basis: ASTM F1136/F1136M (Withdrawn 2025) · ASTM F3393 · RCSC Specification for Structural Joints Using High-Strength Bolts (2020) · library-wide review 2026-10 (no per-item review date). Project edition, tolerances and service conditions must be confirmed against the standard text and supplier documents. Do not estimate unconfirmed values.