A solid lubricant paste applied at high-temperature, corroding and stainless steel fastening points so that the threads do not seize and can be loosened later. It changes the friction coefficient greatly, so the torque value must always be set on the basis of that lubricant.
Key points
- There are metal powder types such as copper and nickel, graphite types, and molybdenum disulfide (MoS2) types, and the service temperature and material compatibility differ for each.
- The torque needed for the same clamp load varies greatly with the lubricant. The lubrication condition of the torque table or K value (nut factor) must be the same as the actual lubricant.
- Apply it to both the threaded portion and the nut bearing face. Bearing face friction also accounts for a large share of the tightening torque.
- For oxygen equipment, do not use hydrocarbon-based lubricants; use only lubricants permitted for oxygen.
- For stainless steel and nickel alloy high-temperature parts, products with limited halogen and sulfur content are sometimes specified (to prevent stress corrosion and high-temperature corrosion).
Checks for BOMs and buying
- If a bolt with anti-seize compound is tightened using a dry (unlubricated) torque table, over-tightening may yield the stud or over-compress the gasket.
- Copper-based compounds are not used where copper must be avoided, such as acetylene and ammonia equipment.
- Whether to apply a lubricant over a PTFE-coated stud follows the conditions of the coating supplier's torque data.
- For sour and high-temperature equipment, the specification sometimes designates the lubricant type, so check first.
These links go to the issuing bodies; they are not the verification source of individual values.
Basis: ASME PCC-1 · NASA RP-1228 · library-wide review 2026-10 (no per-item review date). Project edition, tolerances and service conditions must be confirmed against the standard text and supplier documents. Do not estimate unconfirmed values.