boltnoteSend an RFQ →

Home › Standards glossary › Fastening and joint design › Tightening torque and the K factor

Tightening torque and the K factor

CommonConcept

Tightening torque and nut factor K (T = K·D·F)

← Back to topicSend a BOM or RFQ →

The relation between torque and preload is commonly approximated as T = K·D·F. K (nut factor) is an empirical value that lumps together thread and bearing face friction, so if the lubrication or coating changes, the preload at the same torque changes greatly.

Key points

  • Simple formula: T = K × D × F. In SI, T [N·m] = K × d [m] × F [N], and in inch, T [lbf·ft] = K × D [in] × F [lbf] / 12.
  • Detailed formula (ISO 16047, VDI 2230 family): T = F × (P/2π + 0.577·μth·d2 + μb·Db/2). It is the sum of the pitch term, the thread friction term and the bearing face friction term (d2 pitch diameter, Db mean bearing face diameter).
  • Most of the torque is used up by friction. It is commonly explained as about 50% bearing face friction, about 40% thread friction, and about 10% for stretching the bolt.
  • K is commonly assumed to be 0.2, but it should not be used as is. NASA RP-1228 gives 0.15 as a more realistic typical value for steel on steel. It varies greatly with lubricant and coating, so the actual value is set from the manufacturer's data or by testing.
  • Example: 3/4"-10 UNC, 50 ksi on the As basis → F = 0.334 × 50,000 = 16,700 lbf. With K = 0.20, T = 0.20 × 0.75 × 16,700 / 12 ≈ 209 lbf·ft (283 N·m).
  • Units: 1 lbf·ft = 1.356 N·m, 1 kgf·m = 9.807 N·m, 1 lbf = 4.448 N.

Torque by K at the same preload of 16,700 lbf (3/4"-10, 50 ksi on the As basis)

Assumed KTorque (lbf·ft)Torque (N·m)
0.20209283
0.15157212
0.12125170

Calculated values of T = K·D·F. K values are example assumptions and not the value of any specific lubricant

Checks for BOMs and buying

  • The K (or μ) of the torque table must be the same as the lubrication condition in the field. If anti-seize compound is applied and unlubricated torque is used, the result is over-tightening (bolt yielding, gasket over-compression).
  • Studs with PTFE coating or zinc flake coating with a lubricating topcoat have low friction, so preload is greater at the same torque. Use the torque value for the coating condition (the same intent as the warning in the site's flange calculator).
  • Confusion of torque units (ft·lb, in·lb, N·m, kgf·m) is frequent. State the unit together in the procedure.
  • Normally the nut side is turned. If the bolt head is turned, shank twist and friction conditions differ and the preload differs at the same torque, so set the torque for that condition separately.
  • The presence of a hardened washer and the bearing face roughness also change K. If the washer is removed or changed, set the torque again.

ASME: official search ↗ · ISO: official search ↗

These links go to the issuing bodies; they are not the verification source of individual values.

Basis: ISO 16047 · VDI 2230-1 · ASME PCC-1 · NASA RP-1228 · library-wide review 2026-10 (no per-item review date). Project edition, tolerances and service conditions must be confirmed against the standard text and supplier documents. Do not estimate unconfirmed values.