Flange stud length is used as the first-thread-to-first-thread length with both end points (chamfers) excluded, per the B16.5 table, while a hex bolt (ISO 4014) is measured from under the head bearing face to the end.
Key points
- For a hex bolt (ISO 4014), the nominal length is from under the head bearing face to the end (including the chamfer).
- Stud length in the B16.5 table is used as the first-thread-to-first-thread length, excluding the points. It differs from the overall length measured end to end.
- ASME Interpretation 2-4 (covering B16.5-1988): the stud length in the table does not guarantee that 2 threads protrude beyond the nut. The table length is a value set by the calculation method in the B16.5 appendix (Annex F of the 1988 edition, Appendix C of the 2017 edition).
- RF length examples: Class 150 NPS 8 is 4-1/4", Class 300 NPS 4 and 8 are 4-1/2" and 5-1/2", Class 600 NPS 4 is 5-3/4" (table).
RF stud length examples (points excluded)
| Class · NPS | Bolts × diameter | RF length |
|---|---|---|
| 150 · NPS 8 | 8 × 3/4" | 4-1/4" (RF 1/16") |
| 300 · NPS 4 | 8 × 3/4" | 4-1/2" (RF 1/16") |
| 300 · NPS 8 | 12 × 7/8" | 5-1/2" (RF 1/16") |
| 600 · NPS 4 | 8 × 7/8" | 5-3/4" (RF 1/4") |
Cross-checked against 3 or more public charts from manufacturers and distributors; not yet checked against the original standard. Nominal sizes whose values differ between charts are not listed.
Checks for BOMs and buying
- Check whether the BOM length is the overall length including points, or follows the flange standard's convention (points excluded, etc.).
- Even among public charts, the same nominal length sometimes differs by 1/4" (example: Class 150 NPS 4 RF 3-1/2" and 3-3/4"). Check the chart's source and the edition it applies to.
- When converting an inch length to mm and rounding (3.50" = 88.9 mm), do not shorten it arbitrarily. If it becomes shorter, the thread does not protrude beyond the nut.
- Joints with tensioning allowance, insulating kits, thick gaskets, or wafer-type valves, spacers or orifice flanges cannot use the table length. Calculate separately.
- If an RTJ flange is bought with the RF length, the engagement falls short.
ASME: official search ↗ · ISO: official search ↗
These links go to the issuing bodies; they are not the verification source of individual values.
Basis: ISO 4014 · ASME B16.5 · ASME B16.5 interpretation 2-4 · Cross-checked against three or more manufacturer and distributor datasheets (not yet checked against the original standard) · library-wide review 2026-10 (no per-item review date). Project edition, tolerances and service conditions must be confirmed against the standard text and supplier documents. Do not estimate unconfirmed values.