Dimensions
Basis: DIN 939 · Cross-checked against three or more manufacturer and distributor datasheets (not yet checked against the original standard) · Scope: M6–M42 of DIN 939 (stud end ≈1.25d) — pitch and nut-end thread length for l > 200 mm (a column that does not exist for M6 and M8); DIN 938, 835 and 940 are not included. · Units mm
| Nominal size | b1_939stud end b1 (DIN 939) | b_le125nut-end thread b (l ≤ 125) | b_125_200nut end b (125 < l ≤ 200) | x1incomplete thread x1 |
|---|---|---|---|---|
| M6 | 7.5 | 18 | 24 | 2.5 |
| M8 | 10 | 22 | 28 | 3.2 |
| M10 | 12 | 26 | 32 | 3.8 |
| M12 | 15 | 30 | 36 | 4.3 |
| M14 | 18 | 34 | 40 | 5 |
| M16 | 20 | 38 | 44 | 5 |
| M18 | 22 | 42 | 48 | 6.3 |
| M20 | 25 | 46 | 52 | 6.3 |
| M22 | 28 | 50 | 56 | 6.3 |
| M24 | 30 | 54 | 60 | 7.5 |
| M27 | 35 | 60 | 66 | 7.5 |
| M30 | 38 | 66 | 72 | 9 |
| M33 | 42 | 72 | 78 | 9 |
| M36 | 45 | 78 | 84 | 10 |
| M39 | 50 | 84 | 90 | 10 |
| M42 | 52 | 90 | 96 | 11 |
Need Tap-End Stud to this standard? Send the BOM or drawing as it is. We check against the applicable standard and then quote in KRW for delivery within Korea.
Send a BOM or RFQ →Basis and limits of this table
- Cross-checked against three or more manufacturer and distributor datasheets (not yet checked against the original standard)
- Scope: M6–M42 of DIN 939 (stud end ≈1.25d) — pitch and nut-end thread length for l > 200 mm (a column that does not exist for M6 and M8); DIN 938, 835 and 940 are not included.
- This is not a table from the original standard. Only the values and the standard number are arranged in Boltnote's own format.
- Nominal sizes and columns that could not be confirmed are left out, not estimated.
- For design, inspection and contracts, use the latest edition of the applicable standard and your drawing. Values can change when a standard is revised.
- Checked 2026-10.
- To cite this table: Boltnote Tap-End Stud dimension table, https://boltnote.net/en/tables/tap-end-stud, updated 2026-11-18. Give the basis line above with it.
Sizes or lengths not in the table
Send the BOM or drawing as it is. We check the required dimensions against the applicable standard before quoting.