boltnoteSend an RFQ →

Home › Standards glossary › Bolts, nuts and washers › ASME B18.31.2

ASME B18.31.2

ASMEStandard

Continuous Thread Stud, Double-End Stud, and Flange Bolting Stud (Stud Bolt) (Inch Series)

← Back to topicSend a BOM or RFQ →

General and dimensional standard for inch studs. It covers continuous-thread studs, double-end studs (fastener type and tap-end type), and stud bolts for ASME B16.5 flanges; material is specified separately by ASTM standards.

Status: Current

Key points

  • Continuous-thread stud: the entire length is threaded.
  • Double-end stud: in the fastener type both ends have the same thread and nuts are fitted on both sides. The tap-end type is driven into a tapped hole at one end, and the thread lengths at the two ends differ.
  • Flange stud bolts: used on ASME B16.5 flanges and made of ASTM Committee A01 bolting materials (A193, A320, A453, etc.).
  • The metric edition is ASME B18.31.1M, and inch threaded rod is B18.31.3.

Checks for BOMs and buying

  • Check on the drawing or specification whether the length of a continuous-thread stud is measured to the point (overall length) or excluding the points.
  • When a flange is thicker than standard, as with a pump nozzle, follow the length in the equipment general arrangement (GA) drawing, not the B16.5 table length.
  • For tap-end studs, specify the thread form of the driven end (normal fit or interference fit) and the thread lengths of both ends on the drawing.

Equivalent and superseding standards

  • ASME B18.31.1M Metric stud
  • DIN 976-1 · DIN 938 · DIN 939 Metric continuous-thread and tap-end stud

ASME: official search ↗

These links go to the issuing bodies; they are not the verification source of individual values.

Basis: ASME B18.31.2 · ASME B16.5 · library-wide review 2026-10 (no per-item review date). Project edition, tolerances and service conditions must be confirmed against the standard text and supplier documents. Do not estimate unconfirmed values.