A bolt threaded over its whole length without a head, which tightens a flange with 2 nuts. For inch piping, the basis is ASME B18.31.2 form, ASTM A193 B7 + A194 2H material, and the ASME B16.5 length table.
Key points
- "STUD BOLT" in a plant BOM usually means one set of 1 continuous thread stud + 2 heavy hex nuts.
- Form standards are ASME B18.31.2 for inch and ASME B18.31.1M for metric, and for general metric use DIN 976-1 stud bolts are also used.
- Material is specified by ASTM A193 (high-temperature and general), A320 (low-temperature) and A453 (high-temperature austenitic flange) grades. The most common combination is A193 B7 + A194 2H.
- The specified minimum tensile strength of B7, 125 ksi (about 862 MPa, converted), is the value for the normal diameter range. Values drop for thick diameters, so check the current A193 table.
Representative combinations by service condition (stud → mating nut)
| Condition | Stud | Nut |
|---|---|---|
| General (ambient and moderate temperature, non-sour) | A193 B7 | A194 2H |
| Sour (hardness limited, exposed bolting) | A193 B7M | A194 2HM |
| High temperature (higher than B7) | A193 B16 | A194 7 (or 16) |
| Low temperature (impact test required) | A320 L7 | A194 7 (impact tested nut) |
| Cryogenic | A320 B8 · B8M | A194 8 · 8M |
| Stainless steel, general | A193 B8 · B8M (Class 1 · 2) | A194 8 · 8M |
Commonly used combinations. Confirm the service temperature limit of each grade and the mating nut against the project specification, the applicable code, and the current A193, A194 and A320.
Checks for BOMs and buying
- For lines with only "stud bolt", distinguish whether it is a continuous thread stud for flanges or a tap-end stud driven into a tapped hole at one end.
- Ask back if the number of nuts and the nut grade are missing. B7 + 2H is a common combination, but the nut grade must be written separately in the order.
- Plant bolting over 1" uses a mix of UNC and 8UN (8 threads per inch), which do not mate with each other, so check the thread count in the BOM.
- Check the length basis (whether both end points are included) in the drawing or standard. Studs for hydraulic tensioners have a longer extra thread.
- A stud made from SCM440, SNB7 or 42CrMo4 may be marked B7 only if it satisfies all B7 composition and test requirements.
Equivalent and superseding standards
- ASME B18.31.2 Inch continuous thread, double-end and flange stud forms
- ASME B18.31.1M Metric stud
- DIN 976-1 Metric stud bolt
ASTM: official search ↗ · ASME: official search ↗
These links go to the issuing bodies; they are not the verification source of individual values.
Basis: ASME B18.31.2 · ASME B16.5 · ASTM A193/A193M · ASTM A194/A194M · ASTM A320/A320M · ASME B1.1 · library-wide review 2026-10 (no per-item review date). Project edition, tolerances and service conditions must be confirmed against the standard text and supplier documents. Do not estimate unconfirmed values.