A Unified constant-pitch series with 8 threads per inch (pitch 3.175 mm) regardless of diameter. It is widely used instead of UNC at diameters above 1", and for high-temperature, high-strength bolting, UNC at 1" and below and 8UN above 1" are recommended (NIST H28).
Key points
- 8UN is one of the constant-pitch series of ASME B1.1, and the TPI stays fixed at 8 even as the diameter changes (pitch 25.4/8 = 3.175 mm).
- NIST H28 (3.7) recommends UNC for 0.25 to 1" and the 8-thread series above 1" for high-temperature, high-strength bolting. The ORNL report (1976) commissioned by the US NRC, which evaluated B16.5 flange bolting, also used UNC at 1" and below and 8 threads at 1-1/8" and above.
- The 8 threads at 1" are a standard size of the UNC series, so it is written "1"-8 UNC" (ISO 2306, NIST H28). So the difference between UNC and 8UN begins at 1-1/8" (UNC 7 threads vs 8UN 8 threads).
- At the same diameter the stress area is larger than UNC: 1-1/8" is 0.790 in² (8UN) vs 0.763 in² (UNC), and 1-1/2" is 1.492 in² vs 1.405 in² (about 6%).
Stress area by thread series for bolts of 1" and above
| Nominal size | UNC TPI | UNC As (in²) | 8UN As (in²) |
|---|---|---|---|
| 1" | 8 | 0.606 | 0.606 (same) |
| 1-1/8" | 7 | 0.763 | 0.790 |
| 1-1/4" | 7 | 0.969 | 1.000 |
| 1-3/8" | 6 | 1.155 | 1.233 |
| 1-1/2" | 6 | 1.405 | 1.492 |
| 1-3/4" | 5 | 1.900 | 2.082 |
| 2" | 4-1/2 | 2.498 | 2.771 |
As = 0.7854 (D − 0.9743/n)² (calculated with the formula in NIST H28 Appendix A5)
Checks for BOMs and buying
- If the flange BOM has only "1-1/8" stud" and no TPI, confirm whether it is UNC with 7 threads or 8UN with 8 threads. For high-temperature, high-pressure bolting, 8UN above 1" is recommended (NIST H28).
- When changing only the nuts, check the thread series (TPI) so that UNC nuts are not mixed with 8UN studs.
- Tap-end studs and casing bolts follow the equipment drawing, not the flange rules. They may be UNC even above 1".
ASME: official search ↗ · ISO: official search ↗
These links go to the issuing bodies; they are not the verification source of individual values.
Basis: ASME B1.1 · NIST Handbook H28 · ISO 2306 · library-wide review 2026-10 (no per-item review date). Project edition, tolerances and service conditions must be confirmed against the standard text and supplier documents. Do not estimate unconfirmed values.