The cross-sectional area used when calculating the tensile strength of the threaded portion. For inch, As = 0.7854(D − 0.9743/n)² in², and for metric, As = 0.7854(d − 0.9382P)² mm². It is the basis for proof load and preload stress calculations.
Key points
- Inch (NIST H28 Appendix A5): As = 0.7854 × (D − 0.9743/n)² [in²], D = nominal diameter (in), n = TPI.
- Metric (ISO 898-1): As = (π/4) × ((d2 + d3)/2)², d2 = d − 0.6495P, d3 = d − 1.2269P → As ≈ 0.7854 × (d − 0.9382P)² [mm²].
- Example: 3/4"-10 UNC → 0.750 − 0.0974 = 0.6526 → As = 0.7854 × 0.6526² = 0.334 in² (about 215 mm²).
- Example: M16×2 → 16 − 1.876 = 14.124 → As = 0.7854 × 14.124² = 157 mm².
- Example: the 3/4" shank is 0.442 in² vs As 0.334 in² (about 24% smaller), and the M16 shank is 201 mm² vs As 157 mm² (about 22% smaller). The smaller the diameter and the coarser the pitch, the larger the difference (1/4"-20 is about 35%).
- Proof load = As × proof stress, minimum breaking load = As × minimum tensile strength, bolt stress = preload / As.
- Pressure vessel flange design (ASME BPVC Section VIII Div.1 Appendix 2) uses the root area, not As. Even for the same bolt, the area basis may differ from one calculation to another.
Stress area of commonly used threads
| Thread | As | Converted to mm² |
|---|---|---|
| 1/2"-13 UNC | 0.1419 in² | 91.5 |
| 5/8"-11 UNC | 0.226 in² | 146 |
| 3/4"-10 UNC | 0.334 in² | 215 |
| 7/8"-9 UNC | 0.462 in² | 298 |
| 1"-8 UNC | 0.606 in² | 391 |
| 1-1/8"-8UN | 0.790 in² | 510 |
| 1-1/4"-8UN | 1.000 in² | 645 |
| M12×1.75 | 84.3 mm² | — |
| M16×2 | 157 mm² | — |
| M20×2.5 | 245 mm² | — |
| M24×3 | 353 mm² | — |
| M30×3.5 | 561 mm² | — |
Inch: calculated with the NIST H28 formula, converted to mm · Metric: ISO 898-1:2013 Table 5 values. For UNC values at 1-1/8" and above, see the 8UN item
Checks for BOMs and buying
- Check whether the load calculation used the stress area, the root area or the shank area. Torque tables also give different values if the reference area differs.
- Changing UNC to 8UN increases As (from 0.763 to 0.790 in² at 1-1/8"). Even for the same stress target, use torque and preload tables that match the thread series.
- For reduced-shank (waisted) bolts, the shank may be smaller than As, so judge by the minimum cross-section.
ASME: official search ↗ · ISO: official search ↗
These links go to the issuing bodies; they are not the verification source of individual values.
Basis: NIST Handbook H28 · ISO 898-1 · ASME BPVC Section VIII Division 1 · library-wide review 2026-10 (no per-item review date). Project edition, tolerances and service conditions must be confirmed against the standard text and supplier documents. Do not estimate unconfirmed values.