boltnoteSend an RFQ →

Home › Standards glossary › Material and strength grades › ISO 898-1

ISO 898-1

ISOStandard

Mechanical properties of fasteners made of carbon steel and alloy steel — Part 1: Bolts, screws and studs with specified property classes — Coarse thread and fine pitch thread

← Back to topicSend a BOM or RFQ →

Basic standard that defines bolt property classes such as 8.8, 10.9, and 12.9. It specifies the tensile strength, yield, hardness, and proof load of carbon steel and alloy steel externally threaded fasteners on the basis of room-temperature (10–35 °C) testing.

Status: Current

Key points

  • Scope: coarse thread M1.6–M39, fine thread M8×1–M39×3. Set screws that do not carry tension are covered separately by ISO 898-5.
  • Property classes: 4.6, 4.8, 5.6, 5.8, 6.8, 8.8, 9.8, 10.9, 12.9. 9.8 exists only for d ≤ 16 mm.
  • First number × 100 = nominal tensile strength (MPa), second number × 0.1 = nominal yield ratio. Multiplying the two gives the nominal yield strength (8.8 → 800 × 0.8 = 640 MPa).
  • Acceptance is judged not by the nominal value but by the minimum value in the table. 10.9 is nominally 1000 but has a minimum tensile strength of 1040 MPa, and 12.9 is nominally 1200 with a minimum of 1220 MPa.
  • 8.8, 9.8, 10.9, and 12.9 must be quenched and tempered, and a lower limit of tempering temperature is set (mostly 425 °C).
  • Bolts whose load capacity is reduced by the head shape (countersunk, low head, etc.) have a 0 placed before the property class (08.8, 010.9).
  • Standard note: it assumes use from -50 °C to +150 °C, and use outside it (up to +300 °C) is subject to expert review. For low-temperature and high-temperature materials, it points to EN 10269, ASTM A320, and so on.
  • Drawing designations are split into ISO 898-1, EN ISO 898-1 (European adoption), DIN EN ISO 898-1 (German adoption), and KS B ISO 898-1 (Korean identical adoption), but the editions adopted may differ from each other.

Checks for BOMs and buying

  • KS B ISO 898-1 is the edition identical (IDT) to ISO 898-1:1999 (as shown on the KS portal). The KS designation on Korean drawings and the current ISO edition may differ in test items and designations, so confirm the edition used as the basis for judging certificates.
  • The minimum value of 8.8 splits at a diameter of 16 mm (d ≤ 16: tensile 800 MPa, d > 16: 830 MPa). M16 is judged by the d ≤ 16 value.
  • A property class is a designation for metric fasteners. Do not write it interchangeably with ASTM and SAE grades such as B7 and Grade 5 (the correspondence is approximate).
  • For low temperatures below -50 °C and flange bolting above 150 °C, specify ASTM A320 (low temperature) or A193 (high temperature) or EN 10269 materials instead of a property class.
  • The 010.9 marking on countersunk and low-head bolts means a lower load capacity. Do not expect the load of a 10.9 hex bolt of the same diameter.

Equivalent and superseding standards

  • KS B ISO 898-1 Identical (IDT) to ISO 898-1:1999 - an older edition than the current ISO edition
  • SAE J429 Inch bolt grade system - do not write interchangeably with a property class

ISO: official search ↗ · Korean Standards (KS): official search ↗

These links go to the issuing bodies; they are not the verification source of individual values.

Basis: ISO 898-1 · KS B ISO 898-1 · library-wide review 2026-10 (no per-item review date). Project edition, tolerances and service conditions must be confirmed against the standard text and supplier documents. Do not estimate unconfirmed values.