boltnoteSend an RFQ →

Home › Standards glossary › Inspection, traceability and documents › Hardness (HRC · HRB · HBW · HV) and conversion

Hardness (HRC · HRB · HBW · HV) and conversion

CommonTest

Hardness testing and conversion (Rockwell, Brinell, Vickers)

← Back to topicSend a BOM or RFQ →

The quickest test for confirming the heat treatment condition of a bolt. There are four scales with different indenters and loads, and conversion table values are approximations, so judge by the measured value on the scale set by the standard.

Key points

  • HRC is Rockwell hardness measuring indentation depth with a diamond cone and 150 kgf, and HRB with a 1/16" ball and 100 kgf. HRC is used in the range of about 20 and above, and HRB in the range of about 100 and below.
  • HBW is Brinell hardness obtained from the diameter of the indentation of a tungsten carbide ball (test force up to 29.42 kN = 3000 kgf), and replaces the HB · HBS notation of old editions that used a steel ball.
  • HV is Vickers hardness obtained from the indentation of a diamond square pyramid, used for comparing surface and core and for small parts.
  • Conversion uses the tables of ASTM E140 · ISO 18265, but there is error depending on steel type and heat treatment, so do not decide acceptance by conversion for values near the upper limit.
  • If the surface is too hard compared with the core, suspect carburization; if soft, decarburization. ISO 898-1 tests the two separately.

Hardness ranges set by standards (commonly seen)

SubjectHardnessBasis
ISO 8.8 (d ≤ 16 mm)250–320 HV · 22–32 HRCISO 898-1
ISO 8.8 (d > 16 mm)255–335 HV · 23–34 HRCISO 898-1
ISO 10.9320–380 HV · 32–39 HRCISO 898-1
ISO 12.9385–435 HV · 39–44 HRCISO 898-1
Carbon steel · low-alloy steel, sour exposure≤ 22 HRCNACE MR0175/ISO 15156-2
Baking required after electroplatingSpecified maximum hardness above 390 HV (12.9)ISO 4042

ISO values are from ISO 898-1:2013, the sour limit from the NACE MR0175/ISO 15156 interpretation (A.2.1.2), and ISO 4042 is based on the 2022 edition. The hardness range is judged by the measured value on the scale set by the standard.

Checks for BOMs and buying

  • If a certificate for a soft grade has only an HRC value, below 20 HRC is outside the recommended range of the HRC scale, so request HB · HRB results separately.
  • The value differs by measurement position (on the head, at the thread end, at the section center). Check that it is the value at the position set by the standard.
  • Hardness measured on plating or coating comes out low. Measure at a place where the coating has been removed.
  • Values from on-site portable hardness testers have large conversion errors, so check them against a reference specimen before using them for judgment.

ASTM: official search ↗ · ISO: official search ↗

These links go to the issuing bodies; they are not the verification source of individual values.

Basis: ISO 898-1 · ISO 6506-1 · ASTM E140 · ISO 18265 · ASTM E18 · ASTM E10 · ISO 6507-1 · ISO 4042 · NACE MR0175/ISO 15156 · library-wide review 2026-10 (no per-item review date). Project edition, tolerances and service conditions must be confirmed against the standard text and supplier documents. Do not estimate unconfirmed values.