boltnoteSend an RFQ →

Home › Standards glossary › Material and strength grades › Sour service (H2S) and hardness limits

Sour service (H2S) and hardness limits

NACEConcept

Sour (H2S) service and hardness limits for bolting

← Back to topicSend a BOM or RFQ →

Conditions that limit material and hardness to prevent sulfide stress cracking (SSC), in which high-strength steel absorbs hydrogen in a wet H2S environment and suddenly fractures. For bolting, the grade differs depending on whether it is "exposed" to the sour environment.

Key points

  • The reference is NACE MR0175/ISO 15156 (oil and gas production), and refineries often use NACE MR0103/ISO 17945. ISO 15156-2 covers carbon and low-alloy steels, and ISO 15156-3 covers corrosion-resistant alloys.
  • For carbon and low-alloy steels, ISO 15156-2 sets general conditions such as 22 HRC or less, nickel under 1 %, and not being a free-machining steel.
  • For exposed bolting (bolting that is cut off from the atmosphere by insulation, burial or a flange cover, or that contacts the fluid), reduced-hardness grades such as A193 B7M and A320 L7M + A194 2HM and 7M are commonly used.
  • For flange bolting fully exposed to the atmosphere, using B7/2H is common practice, but whether it applies is decided by the project specification.
  • Plating or PTFE coating cannot substitute for an unsuitable material.

Sour bolting combinations

ConditionBoltNutRemarks
Non-exposed (flange or casing exposed to the atmosphere)A193 B7A194 2HGeneral practice, check the specification
Exposed (insulation, burial, cover, fluid contact)A193 B7MA194 2HMReduced-hardness grades, check the specification
Exposed + low temperatureA320 L7MA194 7M (impact tested)Check the specification

General combinations (grade names only; check hardness values in the current edition of each standard). The applicable standard (MR0175 or MR0103) and the project specification take precedence.

Checks for BOMs and buying

  • If the specification says only "NACE", first confirm whether it is MR0175 or MR0103, and whether the bolting is exposed or non-exposed.
  • Wrapping with insulation or covering the flange with a cover changes non-exposed bolting into exposed bolting.
  • For a B7M certificate, check the hardness results, and if a value below 20 HRC is given only in HRC, get it again in HB or HRB.
  • L43 is of the AISI 4340 family, so its nickel is usually 1.65–2.00 %, above 1 %, and it does not fall under the general conditions for carbon and low-alloy steels in ISO 15156-2; it is therefore not used as exposed sour bolting.
  • B7M cannot be distinguished from B7 by PMI. Confirm it by the markings and the hardness records.

ASTM: official search ↗

These links go to the issuing bodies; they are not the verification source of individual values.

Basis: NACE MR0175/ISO 15156 · NACE MR0103/ISO 17945 · ASTM A193/A193M · ASTM A194/A194M · ASTM A320/A320M · library-wide review 2026-10 (no per-item review date). Project edition, tolerances and service conditions must be confirmed against the standard text and supplier documents. Do not estimate unconfirmed values.