boltnoteSend an RFQ →

Home › Standards glossary › Material and strength grades › Property Class 10.9

Property Class 10.9

ISOGrade

Property class 10.9 (ISO 898-1)

← Back to topicSend a BOM or RFQ →

High-strength bolt grade. Minimum tensile 1040 MPa, 0.2 % proof strength 940 MPa, 320–380 HV. The mating nut is class 10 and the washer is 300HV.

Key points

  • Nominal 1000 MPa × 0.9 = nominal yield 900 MPa (the minimum values for judgment are tensile 1040 and proof strength 940 MPa).
  • Proof stress 830 MPa, hardness 320–380 HV (32–39 HRC), minimum elongation 9 %.
  • Material: carbon steel with boron etc. added, carbon steel, alloy steel, quenched and tempered (tempering 425 °C or higher).
  • Mating: nut class 10 (ISO 4032, 4033), washer 300HV (300–370 HV).
  • Electroplating (ISO 4042): process validation and product testing or baking, at the manufacturer's choice.
  • Hot-dip galvanizing (ISO 10684) covers up to 10.9, but conditions apply such as no high-temperature galvanizing for M27 and above.

Checks for BOMs and buying

  • 10.9 ≈ F3125 A490 (approximate). A490 has an upper tensile limit (173 ksi) and hot-dip galvanizing is prohibited, so do not substitute them as they are (RCSC).
  • For electro-zinc or black zinc 10.9, check by certificate whether baking and process validation were done.
  • Specify a 300HV washer instead of a 200HV mild steel washer.
  • If a class 8 nut is put on a 10.9 bolt, the nut threads may strip first.
  • The 10.9 of the structural HV set (EN 14399-4) and an ordinary 10.9 hexagon bolt differ in dimensions and set requirements.

ISO: official search ↗

These links go to the issuing bodies; they are not the verification source of individual values.

Basis: ISO 898-1 · ISO 898-2 · ISO 898-3 · ISO 4042 · ISO 10684 · library-wide review 2026-10 (no per-item review date). Project edition, tolerances and service conditions must be confirmed against the standard text and supplier documents. Do not estimate unconfirmed values.