boltnoteSend an RFQ →

Home › Products › Bolts & Screws › High Strength Structural Bolting Assembly, Metric

FASTENER PRODUCT GUIDE

High Strength Structural Bolting Assembly, Metric

Core familyCheck metric designations

A bolt, nut and washer set used for steel frame connections. Domestically specified by KS B 1010 (friction grip) and KS B 2819 (torque-shear type), in Europe by EN 14399, and in the US by ASTM F3125 (A325 and A490) + A563 DH + F436.

High Strength Structural Bolting Assembly, Metric reference 3D shape
Reference rendering · not a product photo
Dimensions, material and surface treatment are confirmed against your specification.

Applicable standards and designations to distinguish

The standards below are not a list of interchangeable substitutes with the same dimensions and requirements. We compare against the standard and edition in your BOM and the drawing requirements.

High Strength Structural Bolting Assembly, Metric catalog standard designations
Body / basisStandard and scope
ISOISO 7412 (ISO 4775 nut)
DINDIN 6914 (bolt) · DIN 6915 (nut) · DIN 6916 (washer) → EN 14399-4 · EN 14399-6
KSKS B 1010 set of high-strength hex bolt, hex nut and plain washer for friction grip joints
JISJIS B 1186

Dimension table

Nominal-size dimensions of DIN 6914·6915·6916 (HV set): 7 sizes, M12–M36. Open the High Strength Structural Bolting Assembly, Metric dimension table →

Differences to check before buying

  • A bolt, a nut and 2 washers form one set, and parts from the same lot are used together. Mixing parts from other lots or other standards changes the torque coefficient.
  • Compared with a general hex bolt, the width across flats is larger and the threaded portion is shorter. Example: M20 width across flats 32 mm, thread length 33 mm (EN 14399-4).
  • It is designed on the premise of 1 each under the head and under the nut. Do not remove or add washers on site.
  • Example of choosing the length: clamped thickness + 2 washers + nut height + about 3 threads. In Korea it is supplied in 5 mm steps.
  • Do not reuse a set that has spun freely after tightening (bolt and nut turning together) or a set that has been used once.
  • Hot-dip galvanizing F10T is generally avoided because of the risk of delayed fracture. If plating is needed, decide the grade and coating together at quotation.
Materials and surface treatments we distinguish when reviewing

Material and strength designations

F10T · F8T · HV 10.9/10

Surface treatment designations

Untreated (bare) · Hot-dip galvanizing · Torque coefficient A (surface lubrication treatment) · Torque coefficient B (rust-preventive oil only)

These are review items, not a statement that every combination is available. Confirm against the applicable standard and your service conditions.

What to put in the RFQ for this item

No new form is needed: send your existing BOM, notes or request. Missing specifications come back as questions.

Item: High Strength Structural Bolting Assembly, Metric
Applicable standard and edition: [as written in your BOM or drawing]
Nominal size, pitch, length: [exactly as written]
Material and grade / surface treatment: [your requirement]
Quantity and unit / required date and delivery site: [your request]
Documents: [e.g. EN 10204 3.1, CoC]
Send a BOM or RFQ →

Compiled from the public catalog designations and guidance. A review date is not recorded per item. For design and contracts, check the applicable standard text and your drawing; do not estimate unconfirmed values.

Items to compare

Reference rendering · not a product photo