Grade markings of high-strength bolt sets for steel structures in Korea and Japan. F is the friction grip hex set, S is the torque-shear type set, and the number means the lower limit of tensile strength (× 100 MPa).

Key points

  • Tensile strength by Japanese standards: F8T 800~1000, F10T · S10T 1000~1200 MPa. Proof strength (yield) is F8T 640, F10T · S10T 900 MPa or more.
  • F8T · F10T are the grade markings of KS B 1010 · JIS B 1186. S10T is the marking of the torque-shear type set; in Korea the KS B 2819 set is called this, and in Japan it is an association standard such as JSS II 09.
  • F10T specifies tensile strength as a range up to the upper limit, while ISO 10.9 specifies a minimum of 1040 MPa. They are not the same grade.
  • Japanese road bridges have not used F11T and above as new since 1980 because delayed fracture occurred. KS B 1010 added the 1300 MPa class F13T together with the delayed fracture test in the 2004 revision.
  • In the Japanese building field, there are the ultra-high-strength bolts F14T · S14T certified by the Minister of Land, Infrastructure, Transport and Tourism (tensile strength 1400, proof strength 1260 MPa or more).

Structural high-strength bolt grades (values of Japanese standards)

GradeTypeTensile strength (MPa)Proof strength · yield (MPa)Japanese basis
F8THex bolt set800 ~ 1000640 or moreJIS B 1186 class 1
F10THex bolt set1000 ~ 1200900 or moreJIS B 1186 class 2
S10TTorque-shear type (pintail)1000 ~ 1200900 or moreJSS II 09
F14T · S14THex · torque-shear type1400 or more1260 or moreCertified by the Minister of Land, Infrastructure, Transport and Tourism

Values cited from the Japanese Specifications for Highway Bridges and the Architectural Institute guidelines (Japanese National Institute for Land and Infrastructure Management materials). The values of KS B 1010 · 2819 are not included in this table.

Checks for BOMs and buying

  • Do not replace an F10T set with general 10.9 hex bolts and nuts. The strength and torque coefficient requirements per set differ.
  • S10T and F10T sets have different tightening methods and are not interchanged.
  • The higher the strength, the more sensitive to hydrogen delayed fracture. Avoid pickling, electroplating, and corrosive environments, and if plating is needed, decide it at the design stage.
  • For a BOM that only says "HTB", check whether it is an F10T set or S10T, and the nominal size and length.

Equivalent and superseding standards

  • EN 14399-4 (HV 10.9) European set for the same use, not the same grade
  • ASTM F3125 Grade A490 Inch structural, not the same grade

ISO: official search ↗ · Korean Standards (KS): official search ↗ · JISC: official search ↗

These links go to the issuing bodies; they are not the verification source of individual values.

Basis: JIS B 1186 · JSS II 09 · KS B 1010 · KS B 2819 · ISO 898-1 · library-wide review 2026-10 (no per-item review date). Project edition, tolerances and service conditions must be confirmed against the standard text and supplier documents. Do not estimate unconfirmed values.