The KS for sets of high-strength hex bolts, hex nuts, and plain washers used in friction grip joints of steel structures. Grades use the F8T and F10T designations, and the 2004 revision introduced the 1300 MPa class F13T and a delayed fracture test.
Status: Current
Key points
- Scope: sets of high-strength hex bolts, hex nuts, and plain washers for friction grip joints, used mainly in steel structures.
- Before the 2004 revision, there were three grades, F8T, F10T, and F11T, and the field mainstream was the 1000 MPa class F10T (Korean Agency for Technology and Standards revision commentary).
- The 2004-12 revision added the 1300 MPa class F13T and a hydrogen delayed fracture sensitivity test (revision commentary of the Korean Agency for Technology and Standards, portal history).
- It cites the hydrogen embrittlement preload test KS B ISO 15330, bolt holes KS B ISO 273, and others.
- The KS portal shows no corresponding international standard. Japan's JIS B 1186 also states that it has no corresponding international standard.
Checks for BOMs and buying
- Use a set within the same lot. Mixing parts of different lots or different standards changes the torque coefficient.
- Do not replace an F10T set with general 10.9 hex bolts and nuts. There are torque coefficient and lot requirements per set.
- For torque-controlled tightening, check the torque coefficient value of the set (certificate) and set the tightening torque.
- If plating is needed on an F10T set, examine the delayed fracture risk separately at the design stage.
Equivalent and superseding standards
- JIS B 1186 Correspondence (same grade marking F8T · F10T)
- EN 14399-4 European HV set (same use, not the same standard)
- ASTM F3125 Inch structural bolts (A325 · A490)
Korean Standards (KS): official search ↗ · JISC: official search ↗
These links go to the issuing bodies; they are not the verification source of individual values.