boltnoteSend an RFQ →

Home › Standards glossary › Material and strength grades › Yield strength and tensile strength (bolts)

Yield strength and tensile strength (bolts)

CommonConcept

Yield strength and tensile strength of bolts

← Back to topicSend a BOM or RFQ →

Tensile strength (Rm) is the maximum stress before breaking, and yield strength (ReL·Rp0.2) is the stress at which permanent deformation begins. 8.8 means a nominal Rm of 800 MPa and a yield of 0.8 × 800 = 640 MPa.

Key points

  • Tensile strength Rm = maximum load ÷ cross-sectional area (As for an actual bolt). Yield strength is ReL if there is a distinct yield point, and otherwise the stress at 0.2% permanent elongation, Rp0.2 (0.2% offset in inch standards).
  • For property class "8.8": the first number × 100 = nominal tensile strength (MPa), and the second number × 10 = yield ratio (%). 10.9 → nominal 1,000 MPa, yield 900 MPa.
  • Nominal and minimum differ: 10.9 has a minimum Rm of 1,040 and Rp0.2 of 940 MPa, and 8.8 at d > 16 mm has Rm 830 and Rp0.2 660 MPa.
  • The "70" in stainless steel A2-70 and A4-70 means a minimum tensile strength of 700 MPa, and the "80" in A2-80 and A4-80 means 800 MPa (ISO 3506-1).
  • Full-size testing (the whole bolt is pulled; for bolts with heads, a wedge test) and test piece testing (a specimen machined from bar) can give different values.
  • Units: 1 ksi = 6.895 MPa. Examples: 125 ksi = 862 MPa, 105 ksi = 724 MPa.

Minimum tensile and yield strength of representative classes

ClassMinimum tensile (MPa)Minimum yield (MPa)
4.6400240
8.8 (d ≤ 16 mm)800640
8.8 (d > 16 mm)830660
10.91,040940
12.91,2201,100

ISO 898-1:2013 Table 3 (minimum values)

Checks for BOMs and buying

  • Do not design with the nominal value of the class number; use the standard minimum value and the diameter range (for example, the 16 mm boundary of 8.8).
  • The higher the strength, the more sensitive to hydrogen embrittlement and delayed fracture. For electroplated 10.9 and 12.9, check measures such as baking.
  • Inch-edition (ksi) and SI-edition (MPa) standards set their values separately, so a converted ksi value may differ from the SI-edition value. Check which edition the certificate is based on.

ISO: official search ↗

These links go to the issuing bodies; they are not the verification source of individual values.

Basis: ISO 898-1 · ISO 3506-1 · library-wide review 2026-10 (no per-item review date). Project edition, tolerances and service conditions must be confirmed against the standard text and supplier documents. Do not estimate unconfirmed values.