"A2-70" means austenitic steel grade A2 and property class 70 (minimum tensile 700 MPa). A4 is a steel grade with molybdenum added.
Key points
- Steel grade groups: A austenitic (A1–A5, A8), C martensitic, F ferritic, D duplex. For fasteners, A2 and A4 are the most common.
- A1 to A3 are chromium-nickel types, and A4 to A8 are chromium-nickel-molybdenum types with molybdenum added. A1 is a free-cutting steel grade with increased sulfur, so its corrosion resistance is low (ISO 3506-6).
- Austenitic property class 50 does not apply to A8, and 100 does not apply to A1, A2 and A3.
- Strength is obtained by cold working. Product standards also set lower property classes for large diameters (ISO 4032 nuts: A4-80 up to M24, 50 and 70 above M24).
- Low-carbon steel grades with carbon of 0.030 % or less may add L (A4L-80).
- ISO 3506-1 note: −20 °C to +150 °C can be used without restriction, and −196 °C to +300 °C is left to the user's judgment.
Austenitic bolt property classes (ISO 3506-1)
| Property class | Minimum tensile (MPa) |
|---|---|
| 50 | 500 |
| 70 | 700 |
| 80 | 800 |
| 100 | 1000 |
Property class number × 10 = minimum tensile strength (MPa) (ISO 3506-1). 50 is not available for A8, and 100 is not available for A1 to A3 (ISO 3506-1 Figure 1).
Checks for BOMs and buying
- SUS304 = A2 and SUS316 = A4 are approximate correspondences. If a specific steel grade such as 316L is needed, state it separately.
- For a line that has only "A2" without a property class, ask again for the strength.
- Stainless bolts and nuts of the same kind gall easily. Consider an anti-seize compound and slow tightening.
- Cold-worked austenitic bolts may be weakly magnetic, so do not judge the material by a magnet alone.
- ASTM A193 B8 and B8M (plant bolting) and ISO A2 and A4 have different strength systems, so do not write one as the other.
These links go to the issuing bodies; they are not the verification source of individual values.
Basis: ISO 3506-1 · ISO 3506-2 · ISO 4032 · library-wide review 2026-10 (no per-item review date). Project edition, tolerances and service conditions must be confirmed against the standard text and supplier documents. Do not estimate unconfirmed values.