CommonConcept

Passivation of stainless steel fasteners

← Back to topicSend a BOM or RFQ →

A treatment that dissolves free iron (iron picked up from processing and tools) and contamination from the stainless steel surface with acid and lets the chromium oxide film form evenly. It is not a coating, and color and dimensions hardly change.

Key points

  • The representative standards are ISO 16048 for fastener passivation, and ASTM A967 (chemical passivation) and ASTM A380 (cleaning, descaling and passivation) for general stainless steel parts.
  • There are nitric acid-based and citric acid-based treatments, and after treatment it is checked by water immersion, humidity, salt spray, copper sulfate tests and so on that no free iron remains.
  • Pickling is a stronger treatment that also removes heat treatment and welding scale, while passivation finishes a scale-free surface.
  • For martensitic and precipitation-hardening grades (410, 630, etc.), treatment conditions suited to the material must be chosen. ASTM A967 provides an appendix with guidance on selecting the treatment by steel type.
  • Passivation does not change the corrosion limits of the material. Treating 304 does not make it 316 or duplex for seawater.

Checks for BOMs and buying

  • A "passivation treatment" requirement is meaningful only if the applicable standard (ISO 16048, A967, etc.) and the verification test are stated together.
  • If stainless steel bolts are handled with iron tools or wire brushes, iron particles stick and rust spots form.
  • To tell whether spot rust on a stainless steel bolt is a material problem or surface contamination, look at the surface treatment condition together with the composition.

ASTM: official search ↗ · ISO: official search ↗