Quenched and tempered bolting grade of Cr-Mo steel (4140 family) in ASTM A193. Minimum tensile strength is 125 ksi (converted 862 MPa) up to 2-1/2", and the criterion falls as the diameter gets larger; the mating nut is usually A194 2H.
Status: Current
Key points
- A193 mandatorily follows the A962 common requirements, and points to A320 for low-temperature bolting and to A354 for alloy steel bolting in the lower high-temperature range.
- Minimum tensile/yield by diameter: 125/105 ksi up to 2-1/2", 115/95 ksi over 2-1/2" to 4", 100/75 ksi over 4" to 7" (table).
- The maximum hardness is the same for all diameters: 321 HBW (35 HRC).
- The "diameter" in the table is based on the thread diameter of the finished product, not the bar stock (ASME Interpretation BPV II-A-22-07, SA-193, applicable to the 2017 edition).
- ASME VIII-1 Interpretation VIII-81-68 (1981): to use SA-193 B7 under 2-1/2" down to -50 °F (converted -46 °C), impact testing must be done or the UCS-66 exemption provision must apply.
- MIL-DTL-1222J (US Navy high-reliability fasteners, 2000) accepts commercial A193 B7 but separately requires an upper strength limit, a lower upper hardness limit, and a higher minimum tensile strength for products over 2-1/2".
A193 B7 minimum mechanical properties by diameter
| Diameter | Tensile min | Yield min | Elongation / reduction of area min | Hardness max |
|---|---|---|---|---|
| 2-1/2" or less | 125 ksi (converted 862 MPa) | 105 ksi (converted 724 MPa) | 16 % / 50 % | 321 HBW (35 HRC) |
| Over 2-1/2" to 4" | 115 ksi (converted 793 MPa) | 95 ksi (converted 655 MPa) | 16 % / 50 % | 321 HBW (35 HRC) |
| Over 4" to 7" | 100 ksi (converted 689 MPa) | 75 ksi (converted 517 MPa) | 18 % / 50 % | 321 HBW (35 HRC) |
Checked against public technical data from 3 or more manufacturers and distributors; not yet checked against the original standard. The strength, elongation, and reduction of area of the first two rows were also confirmed to be the same as the A193 of the time by the footnote to MIL-DTL-1222J Table II. MPa values are converted (the last digits may differ from the metric values of A193M).
Checks for BOMs and buying
- If the BOM has only "A193 B7" and no nut, confirm by asking whether the nut is a 2H heavy nut or Grade 7, and also whether it is coated.
- For studs over 2-1/2", the basis is 115 ksi, not 125 ksi (100 ksi over 4") - check the strength value in the clamping force and torque calculation.
- For bolting exposed to H2S, use B7M, not B7 (A320 L7M for low temperature) - ISO 15156-2 A.2.2.4 lists these two grades.
- Do not trust the stamping alone - NRC Bulletin 87-02 reported a case where the actual tensile strength of a bolt stamped B7 was about 55 ksi. Confirm with the certificate and hardness.
Equivalent and superseding standards
- JIS G 4107 SNB7 Corresponding grade of alloy steel bolt material for high-temperature use (A193 B7 is noted for reference in the JIS table). KS D 3755 of the same name has been withdrawn
ASTM: official search ↗ · ASME: official search ↗ · JISC: official search ↗
These links go to the issuing bodies; they are not the verification source of individual values.
Basis: ASTM A193/A193M · ASTM A194/A194M · JIS G 4107 · MIL-DTL-1222J · NRC Bulletin 87-02 · ASME interpretation BPV II-A-22-07·VIII-81-68 · BSEE·LBNL subsea bolting study presentation (2016, citing ISO 15156) · Cross-checked against three or more manufacturer and distributor datasheets (not yet checked against the original standard) · library-wide review 2026-10 (no per-item review date). Project edition, tolerances and service conditions must be confirmed against the standard text and supplier documents. Do not estimate unconfirmed values.