boltnoteSend an RFQ →

Home › Standards glossary › Threads and fits › Bolt hole (clearance hole) diameter

Bolt hole (clearance hole) diameter

ISOConcept

Clearance holes for bolts and screws (ISO 273)

← Back to topicSend a BOM or RFQ →

ISO 273 sets clearance holes for metric bolts in three series: fine (f), medium (m) and coarse (c). For M16: 17 · 17.5 · 18.5 mm.

Key points

  • Hole tolerances of the three series (for reference): fine H12, medium H13, coarse H14.
  • The inside diameter (minimum) of ISO 7089 plain washers is the same as the ISO 273 fine-series hole up to M36 (M12 13, M16 17, M20 21 mm).
  • The coarse series is used where position error is large, such as castings and welded structures, and the bearing face is reduced, so consider a washer.
  • Inch bolt holes follow ASME B18.2.8. The standard hole for steel structures, per RCSC, is bolt diameter + 1/16" for bolts under 1" and + 1/8" for 1" and over.
  • A clearance-hole bolt does not locate position. If position or shear must be taken by the bolt, use a reamer bolt (fitted bolt) or a dowel pin.

ISO 273 clearance holes (mm)

ThreadFine fMedium mCoarse c
M66.46.67
M88.4910
M1010.51112
M121313.514.5
M141515.516.5
M161717.518.5
M20212224
M22232426
M24252628
M27283032
M30313335
M36373942

ISO 273

Checks for BOMs and buying

  • Changing the bolt by looking only at the drawing hole may not fit: a 7/8" (22.23 mm) bolt does not fit in an M20 medium hole (22 mm).
  • Fastening without a washer in a coarse-series hole raises bearing pressure and increases embedding and loosening.
  • The "bolt diameter + 1 mm" practice is the same as the ISO fine series for M12 to M45, but differs for small screws (M10 fine 10.5 mm).

ASME: official search ↗ · ISO: official search ↗

These links go to the issuing bodies; they are not the verification source of individual values.

Basis: ISO 273 · ISO 7089 · ASME B18.2.8 · RCSC Specification for Structural Joints Using High-Strength Bolts · library-wide review 2026-10 (no per-item review date). Project edition, tolerances and service conditions must be confirmed against the standard text and supplier documents. Do not estimate unconfirmed values.