boltnoteSend an RFQ →

Home › Standards glossary › Pins, keys and retaining rings › Retaining ring (snap ring)

Retaining ring (snap ring)

CommonPart

Retaining Ring (Circlip)

← Back to topicSend a BOM or RFQ →

A spring ring fitted in a groove on a shaft or in a hole to keep bearings and gears from slipping out axially. Specified by DIN 471 for shafts, DIN 472 for holes, E-ring DIN 6799, KS B 1336 and 1337, JIS B 2804, and inch ASME B18.27.

Key points

  • The nominal size of a retaining ring for shafts is the shaft diameter, and for holes the hole diameter. It is not the groove diameter.
  • If the lugs (plier holes) are on the outside it is for shafts, and if on the inside it is for holes.
  • The rated load is obtained only when the groove diameter, groove width and groove edge margin match the table.
  • An E-ring cannot take large axial force, so a C-type retaining ring for shafts is used to secure bearings.
  • KS B 1336 is the C-type and KS B 1337 is the E-type retaining ring.
  • Inch rings (ASME B18.27) have different groove dimensions from metric rings and are not interchanged.

Checks for BOMs and buying

  • For lines with only "snap ring", confirm whether it is for shafts (external) or for holes (internal).
  • A ring that has been spread and removed may change shape, so replacing it with a new one at maintenance is the general practice.
  • Zinc electroplating is discussed separately because of hydrogen embrittlement.
  • Wire snap rings (DIN 7993) and rings with lugs (DIN 983 and 984) are different items.
  • Before interchanging a ring marked KS B 1336 with a DIN 471 or 472 ring, compare the groove dimensions.

ASME: official search ↗ · Korean Standards (KS): official search ↗ · JISC: official search ↗ · DIN: official search ↗

These links go to the issuing bodies; they are not the verification source of individual values.

Basis: DIN 471 · DIN 472 · DIN 6799 · KS B 1336 · KS B 1337 · JIS B 2804 · ASME B18.27 · library-wide review 2026-10 (no per-item review date). Project edition, tolerances and service conditions must be confirmed against the standard text and supplier documents. Do not estimate unconfirmed values.