A fully threaded bolt (ISO 4017, DIN 933) is threaded up to the head, while a partially threaded bolt (ISO 4014, DIN 931) has only the thread length b cut and the rest is shank. The shear, fatigue and engagement positions differ, so check when substituting one for the other.

Key points

  • ISO 4014 thread length b (reference values): 2d + 6 for L ≤ 125 mm, 2d + 12 for 125 < L ≤ 200, and 2d + 25 for L > 200. Example: M16 × 100 → b = 38 mm.
  • When the shank is at the shear plane, it resists with the shank cross-sectional area and is stronger than the threaded portion. Steel structure design also divides strength by whether the thread is in the shear plane (N) or not (X).
  • The shank of a partially threaded bolt has a long stretching length, which is advantageous for preload retention and fatigue. A reduced-shank bolt enhances this effect further.
  • ISO 4014 has a minimum length for each diameter (example: M16 is 65 mm); for shorter lengths, use the ISO 4017 fully threaded bolt (ISO 4014:2022).

Checks for BOMs and buying

  • If a shear connection bolt is replaced with a fully threaded one, the thread falls in the shear plane and strength drops.
  • If a partially threaded bolt is replaced by shortening only the length, the threaded portion may be buried inside the plate and the nut cannot be tightened fully. Check the grip length and b together.
  • If the BOM does not distinguish fully and partially threaded, an unwanted type may arrive. Distinguish them by writing the ISO 4014/4017 (DIN 931/933) number.

ISO: official search ↗

These links go to the issuing bodies; they are not the verification source of individual values.

Basis: ISO 4014 · ISO 4017 · library-wide review 2026-10 (no per-item review date). Project edition, tolerances and service conditions must be confirmed against the standard text and supplier documents. Do not estimate unconfirmed values.