The 120 ksi class of heavy hex structural bolts for steel structure connections. Consolidated into the current ASTM F3125, A325 (hex head) and F1852 (TC type, tightened by twisting off the end spline) are included as the same strength grade.
Status: Current (F3125 grade). The standalone standards A325 and F1852 were withdrawn (→ ASTM F3125, 2016)
Key points
- Diameter: heavy hex 1/2" to 1-1/2", and TC type F1852 up to 1-1/4" (F3125 range). Minimum tensile strength 120 ksi (converted 827 MPa) - the withdrawn A325 had two steps of 120/105 ksi, but F3125 has the single 120 ksi.
- Type 1: medium carbon steel, carbon boron steel, alloy steel (including boron-added); Type 3: atmospheric corrosion-resistant (weathering) steel - Type 3 has an underline on the grade symbol.
- Mating parts (RCSC): for uncoated Type 1, A563 C, C3, D, DH, DH3; for plated products DH; for Type 3, C3 and DH3 heavy nuts. A194 2H is allowed instead of C, D, and DH. Washers are F436, of the same Type as the bolt.
- Coating (RCSC): hot-dip zinc (F2329), mechanical zinc (B695 Class 55), and zinc flake (F3393) are possible. Plated nuts are overtapped per A563, and galvanized bolts go through the rotational capacity test as a set with lubricated nuts.
- F1852 (TC type): a Group 120 tension control set tightened by twisting off the end spline. The head marking is A325TC.
- The metric edition grade is F3125M Grade A325M (830 MPa).
Checks for BOMs and buying
- Do not substitute ordinary hex bolts such as A449 or SAE Grade 5 - RCSC specifies structural connection bolts as F3125 Grade A325, A490, and so on.
- Calculations and drawings based on the withdrawn A325 (105 ksi for large diameters) may differ from F3125 (120 ksi) certificate values.
- RCSC (2025): plated and coated bolts and the 150 ksi class cannot be reused. Uncoated A325 heavy hex can be reused for snug-tightened joints; for pretensioned and slip-critical joints, approval of the engineer of record is required.
- Bolt, nut, and washer must be bundled in the same plating process and lot - if only the nut is changed, the rotational capacity test result becomes meaningless.
- KS B 1010 F10T (1000 MPa class), commonly used for steel structure friction-grip connections in Korea, has a different strength system from A325. F10T (tensile 1000–1200 MPa per JIS B 1186) and ISO 10.9 (tensile 1040 MPa or more) are at a similar level but are not the same grade.
Equivalent and superseding standards
- ASTM A325 (withdrawn) Transferred to F3125 Grade A325
- ASTM F1852 (withdrawn) Transferred to F3125 Grade F1852
- ISO 898-1 8.8 A325 at 120 ksi (converted 827 MPa) and 8.8 (800, 830 MPa) are at a similar level but are not the same grade, and dimension and set requirements also differ, so direct substitution is not possible
These links go to the issuing bodies; they are not the verification source of individual values.
Basis: ASTM F3125/F3125M · ASTM A563 · ASTM F436 · RCSC Specification for Structural Joints · library-wide review 2026-10 (no per-item review date). Project edition, tolerances and service conditions must be confirmed against the standard text and supplier documents. Do not estimate unconfirmed values.