The most common bolt plating, in which a thin zinc layer is applied electrolytically and a conversion treatment adds color and corrosion resistance. For high-strength parts, look at hydrogen embrittlement, and for thickness, the thread tolerance.
Key points
- The references for fastener electroplating are ISO 4042 (zinc, zinc-nickel, zinc-iron, cadmium), ASTM F1941/F1941M for inch and metric fasteners, and ASTM B633 and ISO 2081 for general steel parts.
- Color is determined by the conversion treatment (passivation), and there are white (blue-white), yellow, black and others. Hexavalent-chromium-free treatments (trivalent chromium, etc.) are now widely used in place of hexavalent chromium.
- ASTM B633 divides thickness into four standard grades, and the current edition (2023) also provides hexavalent-chromium-free post-treatment types.
- On a 60° thread, the effective diameter grows by about 4 times the plating thickness. An external thread with tolerance allowance such as 6g is plated within that allowance, while a 6h thread with no allowance has its pre-plating dimension reduced or another treatment is chosen.
- ISO 4042: no additional hydrogen-related measure is needed for 9.8 or below; 10.9 requires process validation and product testing, or baking; and 12.9 requires both.
- The friction coefficient differs with the conversion treatment, sealer and topcoat, so the clamp load changes even at the same torque.
Colors and conversion treatments
| Color | Treatment | Remarks |
|---|---|---|
| White (blue-white) | Trivalent clear passivation | No hexavalent chromium |
| Yellow (iridescent) | Formerly hexavalent chromate; now also trivalent treatments (including colored) | For RoHS-regulated products, state "trivalent" |
| Black | Trivalent black passivation | For 10.9 and above, check the baking conditions |
Checks for BOMs and buying
- "YELLOW ZINC" and "colored chromate" on a drawing are notations that commonly meant a hexavalent chromium process, so for RoHS-regulated products, respecify with a hexavalent-chromium-free treatment.
- Hexavalent and trivalent cannot be told apart by color alone. If needed, get a hexavalent chromium non-detection test result.
- For high-hardness parts such as 10.9, 12.9, SAE Grade 8, A574 and spring washers, check the baking conditions or consider zinc flake.
- If thick plating is required, the thread gauge may not go on even a 6g bolt. Specify thickness and thread tolerance together.
ASTM: official search ↗ · ISO: official search ↗
These links go to the issuing bodies; they are not the verification source of individual values.
Basis: ISO 4042 · ASTM F1941/F1941M · ASTM B633 · ISO 2081 · ISO 10684 · library-wide review 2026-10 (no per-item review date). Project edition, tolerances and service conditions must be confirmed against the standard text and supplier documents. Do not estimate unconfirmed values.